New Post: Source key parity error

Hi, i do not know the reason, may be it always checks the parity. I've checked your key and its parity is not adjusted. Try to use adjusted one UE6A4D315D63932332163FBDA8ECCD2BF Regards

View Article


New Post: Font for PIN print

How I can change font for PIN printing with thales payshield 9000?

View Article


Created Unassigned: IBM Pin Verification Key generation using Using VISA ZCMK...

Hi I am not able to find a step to encrypt the a test PVK under VISA ZCMK and generate and Encrypted IBM PVK ( 3624) can some one help

View Article

New Post: Font for PIN print

Using ESC/P codes (Epson Standard Codes for Printer).

View Article

Commented Unassigned: IBM Pin Verification Key generation using Using VISA...

Hi I am not able to find a step to encrypt the a test PVK under VISA ZCMK and generate and Encrypted IBM PVK ( 3624) can some one helpComments: ** Comment from web user: Manshtein ** Hi,If PVK is...

View Article


Commented Unassigned: IBM Pin Verification Key generation using Using VISA...

Hi I am not able to find a step to encrypt the a test PVK under VISA ZCMK and generate and Encrypted IBM PVK ( 3624) can some one helpComments: ** Comment from web user: Manshtein ** Also, could you...

View Article

New Post: Source key parity error

Hi! You have different LMKs, so, the key @mfilippov used on his encironment can not be reused on different HSMs with different LMK. Also, can not be verified. When HSM receivs the key, ed....

View Article

New Post: generating PIN from components

Hi, A4 command awaits LMK encrypted components instead of plaintext. Use Simulator FK console command do form key from plaintext components. Regards, Juris

View Article


New Post: ARQC/ARPC Verification

Hi, The ARQC verification and ARPC generation is not working correctly in simulator, currently. Regards, Juris

View Article


New Post: FA (translate ZPK from ZMK to LMK) command with single length keys

Hi! Check the parameter in ThalesParameters.xml "DoubleLengthZMKs", it should be set to "False" if you want to use single length ZMKs. It is the real HSM "Double ZMK" security parameter analog to...

View Article

New Post: Font for PIN print

Please, can you help me.... How to put this ESC/P code? Directly into the command, PE, JE ? or...

View Article

New Post: Translating IBM PVK using VISA ZCMK

Hi I am running with a project where VISA would verify card holder PINS during Issuer Offline. Now during testing with VISA , VISA has given a requirement where they want the clear PVK to be encrypted...

View Article

New Post: Translating IBM PVK using VISA ZCMK

Hi Also My VISA Test Clear ZCMK is 2034 E62C BC73 FBE6 A764 D3A4 7980 D680 B68C CD45 FB38 C7B3 XOR'ed = 31DC F8CD 3ECB EAD5 And Test IBM Clear 15EA 4CA2 0131 C2FD My key Scheme Z

View Article


New Post: Translating IBM PVK using VISA ZCMK

Hi! You just need to form the Visa ZCMK using console of HSM, FK command and export PVK under formed ZCMK using KE command. Regards, Juris

View Article

New Post: Translating IBM PVK using VISA ZCMK

Hi Manshtein Thank you for your response it helped. Additionally i have a encrypted PVK , is there a way if i want to know what were the clear values? Regards Kingshuk

View Article


New Post: Translating IBM PVK using VISA ZCMK

Hi, Sure. If you want to decrypt the key (eg. PVK) from under LMK, just use the ZMK key with known clear value to export PVK to under ZMK and decrypt the result using usual DES calculator, eg. EFT...

View Article

New Post: hsm 8000 issue

i currently have a thales hsm 8000 . The alarm led is illuminated . on doing a reboot on the hsm the led stays illuminated. i cannot connect via console to the hsm. no matter the serial port settings ....

View Article


New Post: hsm 8000 issue

Hi, Try "Erease" button on front pannel. Press it and hold approx 10 seconds. When you try to connect to console does console returns any output? Regards, Juris

View Article

New Post: hsm 8000 issue

i tried it still the console does not show any output. it always has the alarm and power led on.Shingai Jinguri Senior Systems Engineer Strategic Information Systems Suite 2 Fountain Court, Westgate...

View Article

New Post: hsm 8000 issue

Hi, I am sorry man, but the most probably HSM is dead and needs repairs :( If I am right HSM8000 is out of live few monthes. :/ Sorry Regards, Juris

View Article