New Post: Using M0 Command.
Hi, I am trying to use the M0 command to encryt a pin block.Here is my raw byte command sent to the...
View ArticleNew Post: Thales simulator for commands compatibles RG7000
Hi, I search a version of simulator compatible for RG7000 commands. Someone can help me to download it ?
View ArticleNew Post: Using M0 Command.
Never mind. I got it fixed.The problem was my data length, it was supposed to be 0010 instead of 000F.
View ArticleNew Post: Thales simulator for commands compatibles RG7000
You've certainly come to the right place. Click on Downloads and go from there.
View ArticleNew Post: Thales simulator for commands compatibles RG7000
nickntg wrote: You've certainly come to the right place. Click on Downloads and go from there.Thanks.
View ArticleNew Post: Thales Simulater.
Hi, I just downloaded the Thales simulator and got it up and running. I had done RACAL HSM programming about four years back (such as DC, EC, Pin generation etc). It is been little while I am little...
View ArticleNew Post: Thales Simulator
HI, This is is the first time using the simulator, I tried to send a simple diag command to the SIM and I am getting the following Client: 127.0.0.1:56794 Request: 1234NC No implementor for 1234NC.Not...
View ArticleNew Post: Thales Simulater.
1 - The simulator comes with default LMKs so you don't need to go through that.2 - You need to create your own of course. Different set of LMKs, remember?3 - There's no command to encrypt a clear PIN...
View ArticleNew Post: Thales Simulator
Works for me and I get 1234ND007B44AC1DDEE2A94B0007-E000. Post your configuration along with application events , command events and data received dump.
View ArticleNew Post: Thales Simulater.
Hi Nick, Thanks for your help. I have few more question (just wanted to make it right). I have downloaded the ThalesSim.0.9.6.Mono.2.6.zip is this the right sim to use.When you said create different...
View ArticleNew Post: Thales Simulater.
If you work with Linux, that's the right sim.If you've the clear components to import the ZMK then you can proceed with the same ZMK and then import the ZPK under the ZMK.Regarding the manual, that's...
View ArticleNew Post: Thales Simulator
Hi Nick,Following is the Diag request I am sending to the HSM. On the SIM I do see my command coming in, however I am getting a Command Not found as response from the HSM. Please help, it has been over...
View ArticleNew Post: Problem with import key command
Hi, I have a key under Zmk and I want import this key as Zak under LMK.I send below commands: Online – AUTH> fk Enter LMK id[0-4]: 0 Enter key length[1,2,3]: 2 ( 2*8=16) Enter key type : 000 (ZMK)...
View ArticleNew Post: KQ issue
Hello nickntg, I am sending the HSM command (HSM PayShield 9000) ARQC, the command is HSMCommand KQ:...
View ArticleNew Post: BA Command
Hi Nick, I got the simulator working and am able to communicate with it..... I send a BA command to encrypt the clear PIN FFFF5555 765014034214 (12 Right most PAN) === [BA], starts 20:44:07.214 =======...
View ArticleNew Post: PE command error code 15
Using IBM machine(AS400,Iseries) i have found error code 15 on command PE as below: 1234PA>L>013^0>L>013^1>L>013^2>L>013^3>013 YOUR FULL SERVICE>F 0083PB00...
View ArticleNew Post: CA Command Issues
Hi Nick, Need your help in sorting the issue I am facing I have sent the CA command to the SIM following are the info Application Event: Client: 127.0.0.1:62182 Request:...
View ArticleNew Post: Translate PIN BLOCK from TPK to ZPK error.
Where you able to figure out the issues.
View ArticleNew Post: CA Implementation - Not Working
Hi Nick, Not sure if you had recieved the same concern form other developer. It looks like there might be some issues with the CA implementation. if the Source PIN Format is 1 then it always throws a...
View ArticleNew Post: Thales Simulator
Well I was referring to the data displayed on the simulator's window. If you set the detail level to verbose or debug on the main window and send your command, you should see what the simulator...